The BCA includes requirements for acoustic performance of walls and ceilings to help ensure occupant comfort and privacy. Gyprock has developed a broad range of acoustic systems to help specifiers and builders meet the BCA requirements with confidence. A range of Gyprock's acoustic products are also suitable for use in areas where enhanced acoustic performance will improve the experience of the space.

HD TV

BCA Requirements

HD TV

Class 1 and 10 Buildings

 

For Class 1 buildings with a shared wall such as townhouses, row houses or terraces, requirements for sound insulation requirements are covered in Part 3.8.6 of BCA Volume 2.

Loading component...

Class 2 to 9 Buildings


All other building classes including multi-residential and commercial buildings are covered in the BCA Volume 1 which in part requires:

  • Systems must safeguard occupants from illness or loss of amenity as a result of undue sound being transmitted between adjoining dwellings
  • Separating systems must resist undue sound transmission between dwellings
  • Systems must resist airborne weighted sound Rw or airborne weighted sound with spectrum adaptation Rw+Ctr
  • Floor ceiling systems must also resist impact sounds Lnw
  • Where required wall systems with an impact sound rating must also be of discontinuous construction (i.e. 2 separate leaves without rigid mechanical connection except at the periphery or masonry leaves connected by resilient ties)
  • Systems isolating services between sole occupancy units must resist airborne weighted sound with spectrum adaption Rw+Ctr

Gyprock Acoustic Rated Systems

Gyprock have developed a wide range of systems to meet the acoustic requirements of the BCA.

Loading component...

Class 1 Buildings


For Class 1 buildings Gyprock Party Wall and Boundary Wall Systems are designed for use to provide fire and acoustic separation between attached dwellings.

Loading component...

Loading component...

Other Considerations

Loading component...

Loading component...

Loading component...